Aucom Softstarter EMX4i


Aucom Softstarter EMX4i

Aucom Softstarter EMX4i is a product that you can use in your business that offers fast installation, easy assembly and f/p advantage and has a built-in Bypass contactor.

Current Range

24A-1250A[Nominal]

Fan, Pump, Compressor, etc. applications

Features
- Built-in bypass contactor
- Constant-variable current departure
- Adaptive start-stop adjustment
- DC brake, soft brake, free stop, TVR stop options
- JOG operation (forward-backward)
- Inside delta (6 cables) control
- Reversing contactor control
- Motor thermistor, current imbalance warning, phase sequence fault, phase loss fault (for input and output)
- Clock programmed operation feature
- Built-in analog output
- USB port and data logging
- Work scenario simulation
- Communication options; Modbus RTU, Profibus, DeviceNet, Modbus TCP, ProfiNET, Ethernet IP
- Portable panel option
- Smart pump option card

 

 

ÜRÜN VIDEOSU

Video Bulunamadı

Current Range

25A~1250A (nominal)

Motor Wiring

In-line or inside delta

Bypass Contactor

Internal

 

Power Supply Voltage (L1,L2,L3)

EMX4i-xxxx-V5

200 VAC ~ 525 VAC (± 10%) 

EMX4i-xxxx-V7 

380 VAC ~ 690 VAC (± 10%)

EMX4i-xxxx-V12

1200 VAC (+10%/-20%)

 

Control Supply Voltage (A1,A2,A3)

EMX4i-xxxxB-xx-C1 (A1, A2)

110 VAC ~ 120 VAC (+10%/-15%), 600 mA

EMX4i-xxxxB-xx-C1 (A2, A3)

220 VAC ~ 240 VAC (+10%/-15%), 600 mA

EMX4i-xxxxB-xx-C2 (A1, A3)

24 VAC/VDC (± 20%), 2.8 A

 

Frequncy Range

45Hz ~ 66Hz

Earth Nominal Insulation Voltage

600VAC

Rated Impulse Withstand Voltage

6kV

Digital Inputs

24VDC, 8mA

Motor Termistor (B4,B5)

Trip if greater than 3.6kΩ, reset if less than 1.6kΩ

Relay Outputs

10 A  250 VAC rezistive, 5 A  250 VAC, AC15 pf 0.3

Main Contactor (33, 34)

Normally Open (NO)

Relay Outputs A (41, 42, 43)

Changeable(NO-NC)

Röle Çıkışı B (53, 54)

Değiştirilebilir (NO-NC)

Analog Output (21,22) max load

600Ω (12 VDC, 20 mA), ± 5%

Operating temperature range

-10 °C ~ 60 °C, 40 °C with power reduction on

Humidity Rate It Can Work At

In range of %5 ~ %95 

IP Level

EMX4i-0024B ~ EMX4i-0135B     IP20  

EMX4i-0184B ~ EMX4i-0580B      IP00

EMC Conformity

IEC 60947-4-2, IEC 60947-4-2 Class B

Thermal loss (under energy)

A / 4.5Watt

Thermal loss (working)

  EMX4i-0024B ~ EMX4i-0052B                   ≤ 35 watt

  EMX4i-0064B ~ EMX4i-0135B                 ≤ 50 watt

  EMX4i-0184B ~ EMX4i-0250B                 ≤ 120 watt

  EMX4i-0352B ~ EMX4i-0580B                 ≤ 140 watt